[Pr – 5.07] Brake Active Delay
[Pr – 5.08] Disabled Braking Speed
[Pr – 5.09] Following Error Limit
[Pr – 5.10] AC Line Loss Fault Delay
Description:
Brake Active Delay is the time from when the drive is disabled to
when the brake starts operating.
Range:
0 to 1000
Default:
50
Units:
10 msec
Operating Mode:
All
Description:
Disabled Braking Speed is commanded velocity when drive is
disabled and while brake is operated.
Range:
0 to 1000
Default:
100
Units:
rotary: rpm, linear: mm/sec
Operating Mode:
All
Description:
Following error overflow fault occurs when the difference between
position command and actual position is greater than value set by
this parameter.
Range:
0 to 99999
Default:
20480
Units:
pulse
Operating Mode:
Follower
Description:
AC line loss fault delay is inhibited for this amount of time after loss
of AC power is detected.
Range:
20 to 1000
Default:
20
Units:
msec
Operating Mode:
All