Pr - 0.05] allocation of input signals, Pr - 0.06] allocation of input signals, Pr - 0.07] allocation of input signals – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 30

Publication 2092-RM001A-EN-P — March 2005
2-18
Command Reference
[Pr – 0.05] Allocation of Input Signals
[Pr – 0.06] Allocation of Input Signals
[Pr – 0.07] Allocation of Input Signals
Range:
0 to 8: where 0 = Off, 1 to 7 = digital inputs, and 8 = On.
Data Size:
4 digits
Digits
Digit
Description
Default
0
Drive Enable
0x1
1
Overtravel - Positive 0x8
2
Overtravel -
Negative
0x8
3
Inhibit Integrator
0x0
Operating Mode:
All
Range:
0 to 8: where 0 = Off, 1 to 7 = digital inputs, and 8 = On.
Data Size:
4 digits
Digits:
Digit
Description
Default
0
Fault Reset
0x0
1
Current Limit -
Negative
0x0
2
Current Limit
Positive
0x0
3
Operation Mode
Override
0x0
Operating Mode:
All
Range:
0 to 8: where 0 = Off, 1 to 7 = digital inputs, and 8 = On.
Data Size:
4 digits
Digits:
Digit
Description
Default
0
Preset Direction
0x0
1
Preset Select 1
0x0
2
Preset Select 2
0x0
3
Preset Select 3
0x0
Operating Mode:
All