[Pr – 5.12] Analog Output CH1 Selection
[Pr – 5.13] Analog Output CH2 Selection
[Pr – 5.14] Analog Output CH1 Scale
[Pr – 5.15] Analog Output CH2 Scale
Ultraware Name:
Analog Output 1: Signal
Range:
Refer to Monitor Variables on page A-3 (except 0x0F)
Default:
0x00
Operating Mode:
All
Ultraware Name:
Analog Output 2: Signal
Range:
Refer to Monitor Variables on page A-3 (except 0x0F).
Default:
0x00
Operating Mode:
All
Ultraware Name:
Analog Output 1: Scale
Range:
1 to 5000
Units:
Units depends on the channel selection.
Refer to Monitor Variables on page A-3.
Default:
500
Operating Mode:
All
Ultraware Name:
Analog Output 2: Scale
Range:
1 to 5000
Units:
Units depends on the channel selection.
Refer to Monitor Variables on page A-3.
Default:
500
Operating Mode:
All