Group 4 parameters, Pr - 4.00] current scale, Pr - 4.01] positive internal current limit – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 42: Pr - 4.02] negative internal current limit, Pr - 4.03] positive external current limit, Pr - 4.04] negative external current limit, Group 4 parameters -30

Publication 2092-RM001A-EN-P — March 2005
2-30
Command Reference
Group 4 Parameters
[Pr – 4.00] Current Scale
[Pr – 4.01] Positive Internal Current Limit
[Pr – 4.02] Negative Internal Current Limit
[Pr – 4.03] Positive External Current Limit
[Pr – 4.04] Negative External Current Limit
Range:
0 to 1000
Default:
333
Units:
% of rated continuous current/V *10
Operating Mode:
Analog Current Command, Dual Current Command
Ultraware Name:
Current Limits: Positive Internal
Range:
0 to 500
Default:
500
Units:
% of motor rated continuous current
Operating Mode:
All
Ultraware Name:
Current Limits: Negative Internal
Range:
0 to 500
Default:
500
Units:
% of motor rated continuous current
Operating Mode:
All
Ultraware Name:
Current Limits: Positive External
Range:
0 to 500
Default:
100
Units:
% of motor rated continuous current
Operating Mode:
All
Ultraware Name:
Current Limits: Negative External
Range:
0 to 500
Default:
100
Units:
% of motor rated continuous current
Operating Mode:
All