Pr - 9.05] motor continuous current, Pr - 9.06] motor rated voltage, Pr - 9.07] encoder type – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual

Page 52: Pr - 9.08] hall offset, Pr - 9.09] current constant

Advertising
background image

Publication 2092-RM001A-EN-P — March 2005

2-40

Command Reference

[Pr – 9.05] Motor Continuous Current

[Pr – 9.06] Motor Rated Voltage

[Pr – 9.07] Encoder Type

[Pr – 9.08] Hall Offset

[Pr – 9.09] Current Constant

Ultraware Name:

Ratings: Continuous Current

Range:

1 - 2

15

- 1

Units:

A * 128

Operating Mode:

All

Ultraware Name:

Electrical: Rated Voltage

Range:

10 to 1000

Units:

V

Operating Mode:

All

Ultraware Name:

Feedback: Encoder

Range:

Units Description

1 Incremental

4 Serial

Incremental

5 Serial

Absolute

Operating Mode:

All

Ultraware Name:

Feedback: Hall Input Offset

Range:

0 to 359

Units:

Electrical degree

Operating Mode:

All

Ultraware Name:

General: Torque Constant

Range:

1 - 2

16

- 1

Units:

N * m / A * 4096

Operating Mode:

All