[Pr – 2.10] Preset Velocity 6

[Pr – 2.11] Preset Velocity 7

[Pr – 2.12] Manual Velocity Limit

[Pr – 2.13] Velocity Limit Mode

Control Index

6

Range:

-5000 to 5000

Default:

0

Units:

rotary: rpm, linear: mm/sec

Operating Mode:

Preset

Control Index

7

Range:

-5000 to 5000

Default:

0

Units:

rotary: rpm, linear: mm/sec

Operating Mode:

Preset

Range:

1 to 10000

Default:

10000

Units:

rotary: rpm, linear: mm/sec

Operating Mode:

Follower, Analog Velocity, Preset

Ultraware Name:

Velocity Limits: Velocity Limit Mode

Range:

Value

Description

0x0 Disabled

0x1

Manual Limit - Limited by [Pr – 2.12]
Manual Velocity Limit
.

0x2

Analog Input - Limited by Analog Velocity
Command Value (except Analog Velocity
Mode).

0x3

Manual and Analog - Limited by lesser
one between (Pr-2.12) and Analog Velocity
Command.

Default: