Pr - 2.10] preset velocity 6, Pr - 2.11] preset velocity 7, Pr - 2.12] manual velocity limit – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 39: Pr - 2.13] velocity limit mode
![background image](/manuals/580418/39/background.png)
Publication 2092-RM001A-EN-P — March 2005
Command Reference
2-27
[Pr – 2.10] Preset Velocity 6
[Pr – 2.11] Preset Velocity 7
[Pr – 2.12] Manual Velocity Limit
[Pr – 2.13] Velocity Limit Mode
Control Index
6
Range:
-5000 to 5000
Default:
0
Units:
rotary: rpm, linear: mm/sec
Operating Mode:
Preset
Control Index
7
Range:
-5000 to 5000
Default:
0
Units:
rotary: rpm, linear: mm/sec
Operating Mode:
Preset
Range:
1 to 10000
Default:
10000
Units:
rotary: rpm, linear: mm/sec
Operating Mode:
Follower, Analog Velocity, Preset
Ultraware Name:
Velocity Limits: Velocity Limit Mode
Range:
Value
Description
0x0 Disabled
0x1
Manual Limit - Limited by [Pr – 2.12]
Manual Velocity Limit.
0x2
Analog Input - Limited by Analog Velocity
Command Value (except Analog Velocity
Mode).
0x3
Manual and Analog - Limited by lesser
one between (Pr-2.12) and Analog Velocity
Command.
Default:
0
Operating Mode:
All