Publication 2092-RM001A-EN-P — March 2005

Error Codes, Warnings, and Monitor Variables

A-3

Monitor Variables

This table defines the variables that can be selected for the following
parameters:

[Pr – 5.12] Analog Output CH1 Selection on page 2-35,
[Pr – 5.13] Analog Output CH2 Selection on page 2-35,
[Pr – 5.14] Analog Output CH1 Scale on page 2-35,
[Pr – 5.15] Analog Output CH2 Scale on page 2-35
[Pr – 6.07] Fault Detail Data Selection 1 on page 2-37,
[Pr – 6.08] Fault Detail Data Selection 2 on page 2-37,
[Pr – 6.09] Fault Detail Data Selection 3 on page 2-37, and
[Pr – 6.10] Fault Detail Data Selection 4 on page 2-37.

Variable
Numbers

Name

Ultraware Name

Unit

0x00

Speed Feedback

Velocity Feedback

rpm or mm/sec

0x01

Speed Command

Velocity Command

rpm or mm/sec

0x02

Speed Error

Velocity Error

rpm or mm/sec

0x03

Current Command

Current Command

0.1% of motor rated continuous torque

0x04

Position Feedback

Follower Position

counts

0x05 Position

Command

Master

Position

counts

0x06

Position Error

Position Error

counts

0x07

Position Pulse Command Frequency

Position Command Count
Frequency

0.1 kilocounts/sec

0x08 Electrical

Angle

Commutation

Angle

0.1

o

(degrees)

0x09

Mechanical Angle

Mechanical Angle

0.1

o

(degrees)

0x0A

Regenerative Accumulation Loading Rate

Shunt Power Limit Ratio

%

0x0B

DC Link Rate

Bus Voltage

V

0x0C

Multi-rotation Data of Absolute Encoder

Absolute Rotations

revolutions

0x0D

Speed Command Offset

Velocity Command Offset

mV

0x0E

Current Command Offset

Current Command Offset

mV

0x0F

Input and Output Status

Size: 3 bytes
Bits 1 to 7 = Input Statuses
Bit 8 = Estop
(0 = Normal Operation)
Bits 9 to 11 = Output Statuses
Bit 12 = Fault
(0 = Fault, 1 = No fault)

Input and Output Status

0x10

U phase Current

U Phase Current

0.001 A

0x11

V Phase Current

V Phase Current

0.001 A

0x12

W Phase Current

W Phase Current

0.001 A

0x13

Motor Overload Percentage

Motor Temperature

%

0x14

Analog Velocity Command Voltage

Analog Command - Velocity

0.01 V

0x15

Analog Current Command Voltage

Analog Command - Current

0.01 V

Digital Outputs 3 - 1:
3 and 1 active

Servo Alarm:
No errors

E-Stop:
Not active

Digital Inputs 7 - 1:
6, 5, 3, and 1 active

7

1

3

1

2

3

2

5

4

6