2-39
Group 9 Parameters
[Pr – 9.00] Standard Motor Flag
[Pr – 9.01] Motor Type
[Pr – 9.02] Motor Resistance
[Pr – 9.03] Motor Inductance
[Pr – 9.04] Motor Intermittent Current
Ultraware Name:
General: Motor Flag
Range:
Value Description
0 Custom
1 Standard
Default:
1
Operating Mode:
All
Ultraware Name:
General: Motor Type
Range:
Value Description
0 Rotary
1 Linear
Operating Mode:
All
Ultraware Name:
Electrical: Resistance
Range:
1 - 2
16
- 1
Units:
Ohms * 256
Operating Mode:
All
Ultraware Name:
Electrical: Inductance
Range:
1 - 2
16
- 1
Units:
mH * 256
Operating Mode:
All
Ultraware Name:
Ratings: Intermittent Current
Range:
1 - 2
15
- 1
Units:
A * 128
Operating Mode:
All