Pr - 0.02] basic modes, Pr – 0.02] basic modes -16 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual

Page 28

Advertising
background image

Publication 2092-RM001A-EN-P — March 2005

2-16

Command Reference

[Pr – 0.02] Basic Modes

Operating Mode:

All

Data Size:

4 digits

Digit 0:

Fault and disable braking

Ultraware Name:

Stopping Functions: Fault and Disable Braking

Range: Value

Description

0x0

Brake and hold

0x1

Brake and release

0x2

Free Stop

0x3

Free Stop and hold

Default: 1

Digit 1:

Over-travel stop method

Ultraware Name:

Stopping Functions: Overtravel Stop Method

Range: Value

Description

0x0

Current Control - Stop by normal current. At
the same time, can control current by setting
[Pr – 4.05] Overtravel Current Limit.

0x1

Dynamic brake

Default: 1

Digit 2:

Motor forward direction

Ultraware Name:

Command Polarity

Range: Value

Description

0x0

Normal - Do not invert command signal, so a
positive command value results in CW shaft
rotation (when viewed facing the shaft end).

0x1

Inverted - Invert command signal, so a
positive command value results in CCW
shaft rotation (when viewed facing the shaft
end).

Default: 0

Digit 3:

Power input

Ultraware Name:

Power Input

Range: Value

Description

0x0

AC - Enable AC phase loss detection fault
monitoring.

0x1

DC - Disable AC phase loss detection fault
monitoring.

Default: 0

Advertising