Parameter 215 [Peak Detect1 Out] will contain the positive peak value of
[Motor Spd Fdbk].

To reset the output of the peak detector, parameter 210 [PeakDtct Ctrl In]
toggle on and then off bit 0 “Peak 1 Set”.

Selector Switches

There are two different selector switches available:

A switch that selects between two Dint values. The result is Dint.

A switch that selects between two floating-point values. The result is
floating point.

Two Position Dint Switch

Configuration:

Parameter 1370 [Switch Control] bit 1 “SW Int 1 On” activates the
switch.

The value of parameter 1371 [SW Int 1 NO] is moved into parameter
1373 [SW Int 1 Output] when bit 1 “SW Int 1 On” of parameter 1370
[Switch Control] is on.

The value of parameter 1372 [SW Int 1 NC] is moved into parameter
1373 [SW Int 1 Output] when bit 1 “SW Int 1 On” of parameter 1370
[Switch Control] is off.

[SW Int 1 Output] contains the value of either [SW Int 1 NO] or [SW Int
1 NC].

1371

1372

1370

1

1

0

1373

Switch Control

(SW Int 1 On)

SW Int 1 NO

SW Int 1 NC

SW Int 1 Output