Selector switches – Rockwell Automation 20D PowerFlex 700S with Phase I Control Reference Manual User Manual
Page 178

178
Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013
Chapter 1
Detail Drive Configuration and Operation
•
Parameter 215 [Peak Detect1 Out] will contain the positive peak value of
[Motor Spd Fdbk].
•
To reset the output of the peak detector, parameter 210 [PeakDtct Ctrl In]
toggle on and then off bit 0 “Peak 1 Set”.
Selector Switches
There are two different selector switches available:
•
A switch that selects between two Dint values. The result is Dint.
•
A switch that selects between two floating-point values. The result is
floating point.
Two Position Dint Switch
Configuration:
•
Parameter 1370 [Switch Control] bit 1 “SW Int 1 On” activates the
switch.
•
The value of parameter 1371 [SW Int 1 NO] is moved into parameter
1373 [SW Int 1 Output] when bit 1 “SW Int 1 On” of parameter 1370
[Switch Control] is on.
•
The value of parameter 1372 [SW Int 1 NC] is moved into parameter
1373 [SW Int 1 Output] when bit 1 “SW Int 1 On” of parameter 1370
[Switch Control] is off.
•
[SW Int 1 Output] contains the value of either [SW Int 1 NO] or [SW Int
1 NC].
1371
1372
1370
1
1
0
1373
Switch Control
(SW Int 1 On)
SW Int 1 NO
SW Int 1 NC
SW Int 1 Output