Links, Using the him – Rockwell Automation 20D PowerFlex 700S with Phase I Control Reference Manual User Manual

Page 70

Advertising
background image

70

Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013

Chapter 1

Detail Drive Configuration and Operation

speed 2. Note that the jog command is a maintained type of logic, so that the jog
speed will be active while the jog command bit is maintained.

Links

Links are software connections between two parameters. This allows one
parameter to receive information from another parameter.

Each destination parameter can only have one source parameter. However, source
parameters may be linked to multiple destination parameters. The information
from the link always flows from the source to the destination parameter.

Several default links are set in the drive as default. Modifying these links can be
done two ways:

Using the HIM

Access the destination parameter you wish to use for the link. (This cannot be
done from the ALT Parameter view window, only the parameter list). When you
access the parameter you want to edit, press the ALT, then the View button. This
will display a window with the mode selection. Use the up/down arrow keys on
the top row of buttons to select “Defined Link” and press Enter. When in this
mode, pressing the Select button will allow you to enter the source parameter
number.

17

Jog Speed 2

Applied LogicCmd

152

18

0

18

152

23

Jog Speed 1

0

1

1

Parameter Type

Description

Parameter Symbol

Source

Provides information

Destination

Receives information

Source

Dest.

Information

Source

Source

Dest.

Dest.

Dest.

Information

Information

Advertising