The following is a block diagram overview of the position follower mode:

Speed Reference Selection

For the position following mode to work properly, there needs to be a speed
reference to the speed loop of the drive to follow.

For example, link parameter 12 [Speed Ref 2] to parameter 241 [Encdr1 Spd
Fdbk]. Set parameter 16 [Speed Ref Sel] = 1 “Speed Ref 1". This generates the
speed command from the master encoder input. If a gear ratio is used in the
position loop, parameter 13 [Spd Ref2 Multi] must be setup to match the gear
ratio set in the position loop.

Speed Reference Ramp

The speed reference ramp should be disabled when using the drive as a position
follower. To disable the speed reference ramp, set parameter 151 [Logic
Command] bit 0 “SpdRamp Dsbl” = 1.

Speed Ref

Selection

Linear Ramp

& S Curve

16

Speed Ref Sel

40

43

Speed Control - Reference (2ms)

Selected Spd Ref

S Curve Spd Ref

10

11

12

13

/

*

PI

Regulator

81

82

Spd Reg P Gain

Spd Reg I Gain

300

Motor Spd Fdbk

302

Spd Reg PI Out

Speed Control - Regulator (0.5ms)

Motor Speed Ref

90

Spd Reg BW

301

+

22

743

Aux Posit Ref

Gear Rat

[ N ]
[ D ]

+

Position Offset

PI Regulator

762

Mtr Posit FB

318

Posit Spd Output

Position Control (2ms)

Speed Trim 2

Speed Ref 1

Speed Ref 2

Spd Ref1 Divide

Spd Ref2 Multi

from

Master Encdr

from

Master Encdr

from

Follower Encdr

from

Follower Encdr

Speed Ref

Selection

16

Speed Ref Sel

40

Selected Spd Ref

10

11

12

13

/

*

Speed Ref 1

Speed Ref 2

Spd Ref1 Divide

Spd Ref2 Multi

from

Master Encdr