Functions of the input and output signals, Functions of the input and output, Signals -7 – KEYENCE LK-G Series User Manual

Page 119

Advertising
background image

4-7

4

LK-G-M-NO4-E

4 Input/Output Terminals

Functions of the Input and Output Signals

The following table shows a list of program numbers and how they relate to the status of
terminals P1 through P3.

Comparator output

Alarm output

Input and output signals for measurement control

Auto-zero input

Program No. switch input

Refer to 4-2 for the layout of each terminal.

Name

Description

Reference

page

Tolerance comparator
output
(HI, GO, LO)

Outputted according to the tolerance comparator results.

Page 4-5

Name

Description

Reference

page

Alarm (N.C.) output

Turned on when "–FFFFFF" is displayed due to the alarm
processing (the NPN or PNP open-collector output
transistor is off). Turned off when the normal value is being
held.

Page 4-2

Name

Description

Reference

page

TIMING input

Performs an external synchronization input of the
measurement mode.

Page 4-2

RESET input

Resets the measurement value.

Page 4-2

Name

Description

Reference

page

ZERO input

Sets the current measurement value to zero.

Page 4-2

Name

Description

Reference

page

P1, P2, P3

Changes the program No. by external commands.

Page 4-5