KEYENCE LK-G Series User Manual

Page 34

Advertising
background image

1-14

1

LK-G-M-NO1-E

1 Before Use

LK-G505/LK-G500/LK-G507/LK-G502

The measurement range is shown in the figure below.

*1 The value inside the parentheses ( ) is when the sampling rate is 50 µs.
*2 The value inside the parentheses ( ) is when the sampling rate is 20 µs.
Note that the measurement range narrows in either case, disabling measurements at the
reference position.

• The laser emission LED at both diffuse reflection and specular reflection lights in

green within ±12.5 mm of the reference position, and lights in orange in the other
positions in the measurement range.

• Select the mounting mode (

page 3-12) according to the installation conditions.

When using LK-G505/G500/G507/G502, select function No. G-1 or G-0 (page 33).
The measurement range when measuring a mirror surface or a glass surface at the time of
specular reflection setup is between +173 (NEAR side) to +49.5 mm (NEAR side). When the
sampling rate is 50 µs, the value becomes +173 (NEAR side) to +125 mm (NEAR side). Note
that the measurement is disabled when the sampling rate is 20 µs.

LK-G505

M4r45 mm or more

• Installation procedure

LK-G505

LK-G505

• Diffuse reflection setup

• Specular reflection setup

Reference

distance

500 mm

Reference

distance

0 mm

+249mm
Measurement range
–498mm
(+125mm)

*1

(+230mm)

*2

+250mm
Measurement range
–500mm
(+125mm)

*1

(+230mm)

*2

Reference

distance

497.5 mm

Reference

distance

0 mm

17°

Reference

Note