3 Function Settings

Sample-Hold (Trigger 2)

• When the TIMING input is turned on, the internal measurement value is retained and outputted. That

value is fixed by sampling the data acquired in the same number of times of averaging since the TIMING
input is on.

• In the following cases, the comparator standby status (the display shows "

------

") is displayed until

the first measured value is fixed.
When the power is turned on/when the setting is changed/when the program No. is changed/
when RESET is inputted/when auto-zero is inputted

• The comparator output is outputted according to the measurement value.
• The ON state of each output indicates the state where the NPN or PNP open-collector output is tur ned on.
• The ON state of each input indicates the state where it is short-circuited between the terminal and the

COM terminal for NPN type, and the voltage is applied between the terminal and the COM terminal for
PNP type.

• The RS-232C output is synchronized with the timing input when "Auto transmission" in the Environment

settings is set to other than OFF.

• If the TIMING input is turned on during the RESET process, the system stops the RESET process and

starts sampling.

• When the internal measurement value becomes the alarm state (measurement overrange or inadequate

light intensity), the measurement result varies depending on the settings of the alarm process.
With hold:

The measurement result is outputted by using the value immediately before the retained

value.
Without hold:

The alarm (-FFFFFF) becomes the measurement result.

• If you turn on the RESET input or the ZERO input during the sampling period, the sampling stops and the

comparator standby state is established.

• The TIMING input and RESET input can be controlled via RS-232C (page 5-8).
• The Strobe output time can be changed. Refer to "Setting the Strobe Output Time" (3-44 page) for

details.

• When the mode is set without the alarm hold, and a large value is set for the average number of times, the

measurement result may not trigger an alarm. Check the alarm output to ensure that the alarm state is
properly recognized.

• Set the filter to [Average]. [Count] can be set as desired.

Refer to "Stabilizing the Measurement by Filtering" (3-22 page) for setting the filter.

Sample-and-hold measurement value

Internal measurement value

Comparator

Measurement value

t

process

RESET

Sampling

period

ON

OFF

TIMING output

Comparator standby

(------ display)

Measurement value

ON

OFF

RESET input

ON

OFF

Comparator output

ON

OFF

Strobe output

Binary output

RS-232C output

Sampling

period

Sampling

period

Comparator

Comparator

Measurement value

Measurement value

Measurement

value

Measurement

value

Measurement

value

----------

----------

Reference