KEYENCE LK-G Series User Manual

Page 27

Advertising
background image

1-7

1

LK-G-M-NO1-E

1 Before Use

Operation keys

Terminal panel

1

RS-232C connector

Establishes communication with a PC or a PLC.

2

USB connector

Used when connecting the PC via USB.

Refer to "LK-Navigator User’s Manual" for details.

3

6-pin terminal block

4

Expansion connector

5

Head connectors

6

Laser emission LED.

Lights while the LK-G series operates.

7

Display panel connector

Connects the communication cable between the display

panel and the controller.

8

12-pin terminal block

Key

Function

• During measurement it calls the Program switch mode.

• During measurement it calls the Tolerance setting mode.
• When pressed for one second, it calls the Operation setting mode.
• During setting it cancels the setting content and returns to the previous setting.

• During measurement it calls the Statistics display mode.
• During setting it determines the content.

• During measurement it sets the measurement value to zero.
• When pressed for three seconds it cancels auto-zero.
• When pressed for three seconds while inputting the value, it initializes the selected item.

• During setting it switches the display to the next setting item.
• While inputting the value it shifts one digit right.
• When pressed for one second or more it shifts in higher speed.

• During measurement it changes the display for OUT1, OUT2 or both at the same time.
• During setting it switches the setting content.
• While inputting the value it switches symbols or sets numerical values.
• When pressed for one second or more it shifts in higher speed.

Refer to "Pin Layout" (page 5-2).

Refer to "6-pin I/O terminal block" (page 4-4).

Refer to "Expansion connector" (page 4-5).

Refer to "12-pin I/O terminal block" (page 4-2).

3

6

2

1

7

4

8

5

Advertising