Using the hold function (measurement mode), Using the hold function, Measurement mode) -25 – KEYENCE LK-G Series User Manual

Page 83

Advertising
background image

3-25

3

LK-G-M-NO3-E

3 Function Settings

Using the Hold Function (Measurement Mode)

This section describes the six types of measurement modes.

The function of each measurement mode is as follows.

For the sampling period, Trigger 1 and Trigger 2 are available depending on the trigger setting.

Function No.

Mode name

Description

Reference page

d-0

nor

a

l

Normal

The measured result
can be displayed or
outputted as
required.

page 3-27

d-1

P-k

Peak hold

The maximum value
during the specified
period can be
measured.

page 3-28

d-2

b-k

Bottom hold

The minimum value
during the specified
period can be
measured.

page 3-28

d-3

PP-k

Peak-to-
peak hold

The differential value
of the maximum and
minimum values
during the specified
period can be
measured.

page 3-28

d-4

SP-k

Sample-and-
hold

The value at
the specified
moment can
be measured.

page 3-29, 3-30

d-5

AvG-k

Average
hold

The average value
during the specified
period can be
measured.

page 3-28

Refer to "Setting the Trigger Condition" (page 3-31) for setting the trigger.

Sampling period

Max.value

Sampling period

Min. value

Max. value -
Min. value

Sampling period

TIMING
input

Sample-and-
hold value

Sampling period

Average value

Advertising