KEYENCE LK-G Series User Manual
Page 146

5-16
5
LK-G-M-NO5-E
5 RS-232C
■
Calculation method
* Even when specifying a value from 0 to 3 for the calculation method, specify dummy data for
the calculation between waveforms.
Incoming command
Response command
S
A
O
W ,
S W ,
O A ,
a ,
c ,
c
CR
CR
OUT
number
1 : OUT1 2 : OUT2
Calculation method
0 :
Head
A
1 :
Head
B
2 :
Head
A +
Head
B
3 :
Head
A
–
Head
B
4 :
Head
A
transparent
object
5 :
Head
B
transparent
object
Waveform calculation
0 : 1
1 : 2
2 : 3
3 : 4
4 : 1-2
5 : 1-3
6 : 1-4
7 : 2-3
8 : 2-4
9 : 3-4
■
Starting the ABLE calibration
■
Stopping the ABLE calibration
■
Finishing the ABLE calibration
■
Mounting mode
Incoming command
Response command
S
D
H
W ,
S W ,
H D ,
S ,
h
CR
CR
Head number
1 : Head A
2 : Head B
Incomming command
Response command
S
D
H
W ,
S W ,
H D ,
C
CR
CR
Incoming command
Response command
S
D
H
W ,
S W ,
H D ,
P
CR
CR
Incomming
command
Response command
S
E
H
W ,
S W ,
H E ,
h
CR
,
c CR
Head number
1 : Head A
2 : Head B
Mode
0 :
Diffuse reflection
1 :
Mirror reflection