KEYENCE LK-G Series User Manual

Page 157

Advertising
background image

6-3

6

LK-G-M-NO6-E

6 Specifications of the LK-G Series

*1

The LK-G3001 can be used independently. The measurement value display and the setting
change can be performed on the display panel (LK-GD500) or the Setup support software (LK-
H1W).

• The output rating of the NPN open-collector

50 mA Max. (40 V or less), residual voltage: 0.5 V or less

• The output rating of the PNP open-collector

50 mA Max. (30 V or less), residual voltage: 0.5 V or less

• Non-voltage input rating

ON voltage: 1 V or less, OFF current: 0.6 mA or less

• Voltage input rating

Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA

• Part of each input/output circuit of the LK-G Series is internally common. Be sure that

no potential difference is generated between the common terminals due to the
potential difference between wires or external devices.
Refer to "Precautions for Wiring" (page 4) for details.

RS-232C interface

Measurement data output and control I/O
(selectable up to the baud rate of 115200 bit/s)

USB interface

USB Revision 2.0, Full speed (USB1.1 compatible) com-
pliant

Main functions

2-OUT simultaneous measurement function, Calculation
function, Averaging function, Filter function, Calibration
function, Measurement function, Auto-zero function, Sam-
pling rate setting function, Mutual interference prevention
function, Data storage function, 8-program memory func-
tion, Eco mode, ABLE setting function, Measurement tar-
get setting function, ABLE calibration function,
Transparent object measuring surface selection function,
Statistical computation function, Setup support software
connection function, Head installation selection function,
and others

Rating

Power voltage

24 V DC ±10%. Ripple (P-P): 10% max.

Maximum current con-
sumption

When connecting one measurement head 500 mA or less/
When connecting two measurement heads 600 mA or less

Environmental
resistance

Operating ambient tem-
perature

0 to +50 °C

Operating ambient
humidity

35 to 85% RH (No condensation)

Weight

Approx. 480 g (LK-G3001V/LK-G3001PV)
Approx. 370 g (LK-G3001/LK-G3001P)/
Approx. 60 g (LK-GD500)

Model

Single unit type

LK-G3001V

LK-G3001PV

Separate type *1

LK-G3001/LK-GD500

LK-G3001P/LK-GD500

Advertising