6-13

6

LK-G-M-NO6-E

6 Specifications of the LK-G Series

LK-G505/LK-G500

*1

The value when measuring the KEYENCE standard target (ceramic) in the standard mode. When the sam-
pling rate is 20 µs, the value becomes –230 (NEAR side) to –250 mm (NEAR side) at the time of the diffuse
reflection, and –230 (NEAR side) to –249 mm (NEAR side) at the time of the specular reflection. When the
sampling rate is 50 µs, the value becomes –125 (NEAR side) to –250 mm (NEAR side) at the time of the
diffuse reflection, and –125 (NEAR side) to –249 mm (NEAR side) at the time of the specular reflection.

*2

The value when measuring the KEYENCE standard target (ceramic) in the standard mode

*3

The value when measuring the KEYENCE standard target (SUS) 4096 times average at the
reference distance.

Model

LK-G505/LK-G500

Setting mode

Diffuse reflection

Specular reflection

Reference distance

500 mm

497.5 mm

Measurement range *1

-250 mm to +500 mm

-249 mm to +498 mm

Light source

Red semiconductor laser

Wavelength

650 nm (visible light) class 3R (IEC60825-1)

class

3a (CDRH)

Output

4.8 mW max.

Spot diameter (at reference dis-
tance)

Approx. 300 X 9500 µm (G505)
Approx. ø300 µm (G500)

Linearity*2

±0.05% of F.S. (-250 to +250 mm)
Long range: ±0.1% of F.S. (-250 to +500 mm)
High-accuracy range: ±0.02% of F.S. (-250 to -50 mm)
(F.S.=±250 mm)

Repeatability *3

2 µm

Sampling rate

20/50/100/200/500/1000 µs
(Selectable among six steps)

LED indication

Near the center of measurement range: Lights in green
Within the measurement range: Lights in orange
Outside the measurement range: Flashes in orange

Temperature characteristics

0.01% of F.S./°C (F.S. = ±250 mm)

Environmental
resistance

Enclosure rat-
ing

IP67 (IEC60529)

Operating
ambient light

Incandescent lamp or fluorescent lamp: 10000 lux max.

Operating
ambient tem-
perature

0 to +50 °C

Operating
ambient
humidity

35 to 85% RH (No condensation)

Vibration resis-
tance

10 to 55 Hz, double amplitude 1.5 mm,
2 hours for each of XYZ axes

Material

Aluminum die-cast

Weight (including cable)

Approx. 380 g