LK-G3001PV/LK-G3001P (PNP type)

Precautions when connecting to computers or other external devices

When working in a positive grounding environment, when the LK-G is connected to a
computer through USB in order to use LK-Navigator or when establishing RS-232C
communication with a computer, take precautions to avoid shorts in between the SG
(GND) terminals for the computer and the LK-G.

24 VDC (-), SG (GND) of USB, and SG (GND) of RS-232C are all common via a choke coil.
Make sure that a voltage potential difference does not occur with external devices such as
computers or PLC. If a voltage potential difference occurs, use with insulation on the LK-G
power supply and the I/O terminals other than RS-232C and USB.

LK-G3001P(V)

LK-G3001P(V)

COM OUT

COM IN

DC24V(+)

DC24V(-)

DC24V

COM OUT

COM IN

DC24V(+)

DC24V(-)

DC24V

The power supply (24 VDC) shorts via the
COM terminals, causing malfunctions.

GND

GND

The power supply (24 VDC) shorts via
the SG (GND) terminals for LK-G and
the computer, causing malfunctions.
Insulate the computer (

➀ in the figure)

and LK-G (

➁ in the figure).

* The internal wiring in the computer,
PLC, or other device differs
depending on the device. For details,
refer to the instruction manual for each
device.