Timing Chart

■

When the measurement mode is other than sample hold (trigger 2)

• When the measurement mode is set to normal, the measurement value of when the timing

input turns on is outputted.

• When the measurement mode is peak hold, bottom hold, peak-to-peak hold, average

hold or sample hold (trigger 1), the measurement value that is fixed by turning on the
timing input is outputted.

■

When the measurement hold is sample hold (trigger 2)

• After the timing input turns on, the measurement value fixed after the sampling period

+t ms is outputted.

The t-time is identified as follows.

Sampling rate

20 µs

t=T2+4 ms

Other than 20 µs t=T2+3 ms

Refer to page 4-16 for T2 (input response time).

TIMING input

Measurement

value

t ms

RS-232C data output

ON
OFF

TIMING input

Measurement

value

Sampling period + t ms

RS-232C data output

ON