3 Function Settings

Setting the Head

This section describes the settings related to the sensing for stable detection.

List of Functions and Function Nos.

* The shaded cells

are set by default.

List of Default Values and Setting Ranges

Function Function

Function No.

Reference page

Function
display

0

1

2

3

4

A

Light intensity

adjustment

AUTO

MANUAL

3-5

able

Auto

anual

b

Measurement
mode

Normal

Translucent

object

Transparent

object

Transparent

object 2

Multi-reflective
object

3-7

EAS

nor al

KAlF-t

tran-i

tran-2

rs

Alarm process

Count setting (

[oUnT

, 0 to 999, 8)

Level (

LEVEL

, 0 to 9, 4 )

3-8

ALAr

d

ABLE
calibration

START/STOP

3-10

aBle-t

STart

/

stop

e

Mounting
mode

Diffuse
reflection

Mirror
reflection

3-12

oUnt

d FF-S

rr-S

Function

Item

Settable range

Default value

Remarks

A

ABLE

Auto/Manual

AUTO

Upper limit of control

1 to 99

99

Lower limit of control

1 to 99

1

b

Measurement mode

Normal / Translucent object / Transparent object
/ Transparent object 2 / Multi-reflective object

Normal

[

Number of times of processing

0 to 999

8

Level

0 to 9

4

d

ABLE calibration

START/STOP

-

e

Mounting mode

Diffuse reflection / Mirror reflection Diffuse

reflection