3 Function Settings

Setting the Common Function

This section describes the functions common to each program No.

List of Functions and Function Nos.

* The shaded cells

are set by default.

* Function "F" sets the number of data and accumulation rate as a sub-function.

List of Default Values and Setting Ranges

Function

Function

Function No.

Reference

Function display

0

1

2

3

4

5

page

A

Sampling rate

20 µs

50 µs

100 µs

200 µs

500 µs

1000 µs

3-39

Y LE

20

50

100

200

500

1000

b

Mutual interference
prevention

OFF

ON

3-40

AltEr

oFF

on

Timing synchronization

Asynchronous Synchronous

3-41

Syn

n-Syn[

Syn

d

Comparator output format

Normal

HOLD

Off-delay

3-42

o-For

nor al

xoLd

delay

E

Strobe time

2 ms

5 ms

10 ms

20 ms

3-43

S-t

E

2

5

10

20

F

Data storage

OFF

OUT1

OUT2

OUT 1 , 2

3-44

d-Str

oFF

oUt1

oUt2

oUt1.2

Refer to "Accumulating the Measurement Value in the Memory (Data Storage Function)"
(page 3-54).

Function

Item

Settable range

Default value

Remarks

A

Sampling rate

20/50/100/200/500/1000 µs

200 µs

b

Mutual interference prevention

ON/OFF

OFF

Timing synchronization

Synchronous/asynchronous

Asynchronous

d

Comparator output format

Normal/hold/delay

Normal

E

Strobe time

2/5/10/20 ms

2 ms

F

Data selection

OFF/OUT1/OUT2/OUT1.2

OFF

Number of data

1 to 65536

65536

Accumulation rate

1/2/5/10/20/50/100/200/500/1000

x 20