Mount the 2 inch or 3 inch flange adaptor to the
media take-up flange according to the size of
the tube in the roll media to be spooled.

z

Mounting a 2 Inch Tube

Mount flange adaptor L (a) on the left flange

and flange adaptor R (b) on the right flange
such that the corrugations in the holes are
aligned with the flange grooves.

z

Mounting a 3 Inch Tube

Mount flange adaptor L (c) on the left flange

and the flange adaptor R (d) on the right flange.

Important

z

For both the 2 inch and 3 inch tubes, the flange
adaptor with the spacer is located on the left side, and
the flange adaptor without the spacer is on the right.
Thoroughly check which adapters correspond to the
left and right sides before mounting them.

z

If using adhesive media and the flange adaptor is dirty,
wipe the dirt from the flange adaptor using a cloth.
Continuing to use a dirty flange adaptor may cause
defective spooling.

4

Move the slide holder to the left while
pressing the slide holder release lever (a).

5

Insert the tube into the spool holder axis.

Important

z

Make sure to use roll media for spooling that is the same
size as the tube installed in the media take-up unit.

a

c

b

d

e

f