2 set holdoff period, 1 set backup holdoff period – Comtech EF Data CRS-311 User Manual

Page 108

Advertising
background image

CRS-311 1:1 Redundancy Switch

Revision 7

Modem, RMI/TMI, and Switch Configuration MN/CRS311.IOM

4–18

Follow these steps to enable 

Auto On

 mode: 

 

Step

Task

1

Go to the CONFIG Æ AUTO menu and select AUTO ON mode.

2

Verify that the Stored Event LED stops blinking.

4.6.1.2 Set Holdoff Period

holdoff  period  prevents  unwarranted  backups  due  to  an  intermittent  fault.  When  in 

Auto

mode, additional delays may be introduced to the backup procedure by setting the number of 
seconds  for    "holdoff"  before  the  faulted  Traffic  Modem  cedes  operation  to  the  Redundant 
Modem  (backup),  or  operation  is  returned  from  the  Redundant  Modem  back  to  the  Traffic 
Modem (restore).  
 
The process is further explained: 
 
If  a  fault  occurs  in  the  Traffic  Modem,  and  the  Redundant  Modem  operation  is  fault‐free, 
backup  is  initiated  once  the  configured  Backup  Holdoff  Period  lapses.  However,  if  the  fault 
clears within the holdoff’s configured timeframe, no transfer of operation occurs.  
 
Similarly, if a fault occurs in the Redundant Modem while it is online, and the Traffic Modem’s 
operation is fault‐free, restore is initiated once the configured Restore Holdoff Period lapses.  
The default holdoff period is 10 seconds (a minimum of 1 second and a maximum of 99 seconds 
is allowed).   

4.6.1.2.1

Set Backup Holdoff Period

If the Traffic Modem fails, the Switch waits for the backup holdoff time to determine two things: 
 

1) Does the Traffic Modem remain faulted?  

 

 

 

 

 

and 

 
2) Is the Redundant Modem not exhibiting the same fault?  

 

If the answer is yes to both questions for the entire Backup Holdoff Period, then the Switch first 
bridges  the  faulted  Traffic  Modem  with  the  Redundant  Modem.  If  the  fault  is  sustained,  then 
the switchover to the Redundant Modem is completed and the Redundant Modem carries the 
traffic. 
 
There will be no switchover if the Redundant Modem is faulted. Ensure that the Holdoff times 
are long enough (default  10 seconds) for the Redundant Modem to be configured and to lock 
onto the signal.  
 

Advertising