CRS-311 1:1 Redundancy Switch

Revision 7

Cables and Connections

MN/CRS311.IOM

3–13

3.2.6

IF Connections – User to CRS-281x Module to Modems

The CRS‐281x module connects the online  modulator's Tx IF signal to your  RF Up Converter. It 
also passively splits the receive IF signal to provide both demodulators with the same IF signal 
coming from the LNB, thus reducing switching time. 
 
For 70/140MHz IF switching, the CDM‐Qx uses the CRS‐281 IF Switch Module with either 50Ω or 
75Ω BNC connectors 
 
The CRS‐281A IF Switch Module is intended for use with the CDM‐QxL for L‐Band with Type ‘N’ 
connectors.  This  model  also switches  all  of  the  BUC  and  LNB  interface  signals  that  are 
multiplexed onto the transmit and receive coaxial cables, including: 
 

• Tx and Rx L‐Band signals 

 

• 10 MHz reference to BUC and LNB 

 

•  DC Power to BUC and LNB 

 

•  FSK signaling to the BUC 

 

 

To  prevent  problems  resulting  from  an  impedance  mismatch,  ensure  that  the 
impedance for the modem’s cables and combiner are the same. 

 
Referring to Figure 3‐7 and Figure 3‐8, connect and secure the IF cable pairs – PL/0946‐1 50Ω or 
PL/0813‐4  75Ω  Type  ‘BNC’  or  CA/RF10453‐4  Type  ‘N’  –  between    your  Up/Down  Converters, 
CRS‐311, and CDM‐Qx/QxL modems as follows: 
 
Traffic Modem Connections: 
 

• From  the  CDM‐Qx/QxL  connector  labeled  “Rx”,  to  the  CRS‐281x  Switch  Module 

connector labeled “J1 Rx”, and 
 

• From  the  CDM‐Qx/QxL  connector  labeled  “Tx”,  to  the  CRS‐281x  Switch  Module 

connector labeled “J2 Tx”. 

 
User Connections: 
 

• From your Down Converter, to the CRS‐281x Switch Module connector labeled “J3 Rx”, 

and 
 

• From your Up Converter, to the CRS‐281x Switch Module connector labeled “J4 Tx”. 

 