Ethernet M&C Connections – CRS-311 to User

The  Ethernet  Monitor  and  Control  (M&C)  Connection  differs  depending  on  which  optional 
Ethernet Interface Module and Ethernet Traffic Mode is used with the SLM‐5650/5650A:  
 

The single‐port 10/100/1000 BaseT (GbE) Interface Module, or  

 

The multi‐port Network Processor (NP) Interface Module. 

3.3.5.1 Single-Port Ethernet Bridge Mode M&C Using the GbE Interface

Module

Referring to Figure 3‐12: 
 
If the single‐port 10/100/1000 BaseT (GbE) Interface Module is installed for use in Single‐Port 
Ethernet  Bridge  Mode
  (see  Sect.  3.3.6.1)  and  the  CRS‐311  is  configured  with  the  CRS‐306  or 
CRS‐307 RMI, and CRS‐316 or CRS‐336 TMI,  you must connect only to the “J5 Ethernet” port on 
the Redundant and Traffic modems. 
 
You  can  have  a  single‐point  connection  via  use  of  user‐provided  CAT5  cables  and  a  user‐
provided Layer 2 Ethernet switch. 
  
Referring to Figure 3‐13: 
 
If the single‐port 10/100/1000 BaseT (GbE) Interface Module is installed for use in Single‐Port 
Ethernet Bridge Mode 
(see Sect. 3.3.6.1) and the CRS‐311 is configured with the CRS‐505 RMI 
and CRS‐515 TMI, you must connect only to the “J5 Ethernet” port on the Redundant and Traffic 
modems. Be sure to use the same port number that was used for all corresponding interfaces 
(User Data/RMI/TMI) – in the example shown, “Port 3” is used. 
 
You  can  have  a  single‐point  connection  via  use  of  user‐provided  CAT5  cables  and  a  user‐
provided Layer 2 Ethernet switch. 

3.3.5.2 Multi-Port Ethernet Bridge Mode M&C Using the Network

Processor (NP) Interface Module

 Referring to Figure 3‐14
 
If  the  multi‐port  Network  Processor  (NP)  Interface  Module  is  installed  for  use  in  Multi‐Port 
Ethernet Bridge Mode 
(see Sect. 3.3.6.2), you must connect only to the “J5 Ethernet” port on 
the  Redundant  and  Traffic  modems.    You  can  have  a  single‐point  connection  via  use  of  user‐
provided CAT5 cables and a user‐provided Layer 2 Ethernet switch. 
 

 

Because  “Port  1”  on  the  TMI/RMI  incorporates  a  Gigabit  Ethernet  switch,  it  is 
important 

not

 to use this port. 