Introduction

MN/CRS311.IOM

1–4

• CRS‐281  (70/140 MHz IF) with Type ‘BNC’ (75Ω) connectors 

 

• CRS‐281L (L‐Band IF) with Type ‘N’ (50Ω) connectors 

 

Two CRS‐281x switch modules are compatible for use with the SLM‐5650/5650A modem: 
 

• CRS‐281 (70/140 MHz IF) with Type ‘TNC’ (50Ω) connectors. 

 

• CRS‐281L (L‐Band IF) with Type ‘N’ (50Ω) connectors. 

 

 

The SLM‐5650/5650A modem permits simultaneous operation of the Tx IF and Rx IF 
bands  at  70/140  MHz  and  L‐Band  frequencies,  independent  of  one  another.  If  you 
want  the  Tx  and  Rx  to  be  of  different  IF  bands,  the  CRS‐281x  module  must  be 
selected based on the 
Tx IF band. An external splitter is then used for the Rx IF band 
when that side differs from the Tx IF band – see 
Figure 3‐19 and Figure 3‐20 in Sect. 
3.3.6 IF Connections – User to CRS‐281x to Modems for configuration examples. 

 
See  Sect.  1.3.6  CRS‐281x  IF  Switch  Modules  and  Sect.  1.4.2  CRS‐281x  IF  Switch  Module 
Specifications
 for more information on these switch modules and their specifications. 
 
CRS‐351 Option: Where protection of the overhead  signals (backward alarms, audio ESC, data 
ESC, etc.) is desired, the CRS‐351 Overhead Module may be added. 
 