Comtech EF Data CRS-311 User Manual

Page 79

Advertising
background image

CRS-311 1:1 Redundancy Switch

Revision 7

Cables and Connections

MN/CRS311.IOM

3–31

3.3.6.3 Ethernet Router Mode Data Traffic via the Optional Network

Processor (NP) Interface

When  the  SLM‐5650/5605A  modems  are  equipped  with  the  optional  multi‐port  Network 
Processor (NP) Interface Module, Multi‐Port Ethernet Router Mode is possible. 
 
Referring to Figure 3‐20,  connect and secure all PP/CAT5FF3FTGY CAT5 Data Cables as follows: 
 

• From the RJ‐45 connectors labeled “Port 1” through “Port 4” on the RMI or TMI, to the 

RJ‐45  connectors  ports  labeled  “1”  through  “4”  on  the  Redundant  or  Traffic  Modem 
optional Network Processor (NP) Interface Module. 

3.3.6.4 Ethernet BPM Mode Data Traffic via the Optional Network

Processor (NP) Interface

 

Appendix  E,  Sect.  E.3  Network  Processor  (NP)  Interface  BPM  (Bridge  Point‐to‐
Multipoint)  Mode  in  the 
SLM‐5650A  Satellite  Modem  Installation  and  Operation 
Manual (CEFD P/N MN‐SLM5650A) 

 
When  the  SLM‐5650/5605A  modems  are  equipped  with  the  optional  multi‐port  Network 
Processor (NP) Interface Module, Ethernet BPM Mode is possible.  
 
Referring to Figure 3‐21 , connect and secure all PP/CAT5FF3FTGY CAT5 Data Cables as follows: 
 

• From the RJ‐45 connector labeled “Port 1” on the RMI or TMI, to the RJ‐45 connector 

labeled “J5 Ethernet” port on the Redundant or Traffic Modem. 
 

• From the RJ‐45 connectors labeled “Port 2”, “Port 3”, and “Port 4” on the RMI or TMI, to 

the RJ‐45 connectors ports labeled “1”, “2”, and “3” on the Redundant or Traffic Modem 
optional Network Processor (NP) Interface Module. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertising