CRS-311 1:1 Redundancy Switch

Revision 7

Cables and Connections

MN/CRS311.IOM

3–24

3.3.5.3 Multi-Port Ethernet Router Mode M&C Using the Network

Processor (NP) Interface Module

Referring to Figure 3‐15: 
 
If  the  multi‐port  Network  Processor  (NP)  Interface  Module  is  installed  for  use  in  Multi‐Port 
Ethernet Router Mode 
(see Sect. 3.3.6.3), you must only connect to any one of the NP Interface 
Module’s four Ethernet ports on the Redundant and Traffic modems. The “J5 Ethernet” port is 
not used with this configuration

 
  You  can  have  a  single‐point  connection  for  both  Ethernet  M&C  and  Ethernet  Data  via  use  of 
user‐provided CAT5 cables and a user‐provided Layer 2 Ethernet switch. 
 

 

Because  “Port  1”  on  the  TMI/RMI  incorporates  a  Gigabit  Ethernet  switch,  it  is 

important

 to use this port for the Ethernet M&C connection.

3.3.5.4 Multi-Port Ethernet BPM Mode M&C Using the Network Processor

(NP) Interface Module

Referring to Figure 3‐16: 
 
If  the  multi‐port  Network  Processor  (NP)  Interface  Module  is  installed  for  use  in  Multi‐Port 
Ethernet  BPM  (Bridge  Point‐to‐Multipoint)  Mode 
(see  Sect.  3.3.6.4),  you  can  have  a  single‐
point  connection  for  both  Ethernet  M&C  and  Ethernet  Data  via  use  of  user‐provided  CAT5 
cables and a user‐provided Layer 2 Ethernet switch. 
 

 

Because  “Port  1”  on  the  TMI/RMI  incorporates  a  Gigabit  Ethernet  switch,  it  is 

important

 to use this port for the Ethernet M&C connection. 

 