CRS-311 1:1 Redundancy Switch

Revision 7

Serial-based Remote Product Management

MN/CRS311.IOM

6–10

Parameter Type

Command
(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes:

i.e., ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and qualifier)

Response to query

(Target-to-Controller)

Clear All Stored
Events

CAE= None

Command

only.

Instructs the unit to clear all Stored Events.
This command takes no arguments.

CAE= (message OK)
CAE* (message OK, but not
permitted in current mode)

N/A

N/A

Config Load

CLD=

1 byte, numerical, 0
to 9

Command only.
Forces the Switch to retrieve the Configuration Memory location
defined by the argument n (0 to 9) and to re-program the Switch
with that stored configuration.

CLD= (message OK)
CLD? (received OK, but
invalid arguments found)
CLD* (message OK, but the
memory location does not
contain configuration info)

N/A

N/A

Config Store

CST=

1 byte, numerical, 0
to 9

Command or Query.
The command forces the Switch to store its current configuration in
the Configuration Memory location defined by the argument n (0 to
9).
Example: CST=4 (Store current configuration in location 4)
WARNING: Use with caution! If the location already contains data,
it will be automatically overwritten. If in doubt, query the location
first.
The query returns the contents of the location.

CST= (message OK)

CST? (received OK, but
invalid arguments found)
CST* (message OK, but not
permitted in current mode)

CST?n

where n is 0 to 9

Returns the same format as
the SGC, with the form:
CST=xxx....xxx for a valid
config, and
CST* where no valid config
is found

Date

DAY=

6 bytes, numerical Command or Query.

The date, in the form ddmmyy (international date convention),
where:
dd = day of the month, between 01 and 31,
mm = month of the year, between 01 and 12, and
yy = year, between 97 and 96 (1997 to 2000, then 2000 to 2096)
Example: DAY=240457 would be April 24, 2057.

DAY= (message OK)

DAY? (received OK, but
invalid arguments)
DAY* (message OK, but not
permitted in current mode)

DAY?

DAY=ddmmyy
(see description of
arguments)

Equipment ID

N/A

4 bytes, alpha-
numeric

Query only.
Unit returns information concerning the equipment identification.
S311 indicates this CRS-311 1:1 Switch unit.
(S300 indicates CRS-300 1:N Switch).

N/A EID?

EID=xxxx
(see description of
arguments)

Advertising