Comtech EF Data CRS-311 User Manual

Page 190

Advertising
background image

CRS-311 1:1 Redundancy Switch

Revision 7

Appendix D

MN/CRS311.IOM

D–2

 

d. The “Stored Event” LED on the CRS‐311 Front Panel will flash at twice the current rate when 

Independent Mode is enabled. 

 
e. Independent Mode is selectable via the Front Panel menu or remote control command: 
 

i. To configure via the CRS‐311 Front Panel menu:  

 
• Use  the  ◄  ►arrow  keys  to  select  UTIL Æ INDEP-MODE,  and  then  press 

[ENTER];  

 

• Use the ◄ ►arrow keys to select NORMAL-OP or ENABLE-INDEP, and then press 

[ENTER]

 

ii. To  configure  via  remote  control  command:  IMS=xwhere:  x=0  (Independent  Mode 

disabled) or x=1 (Independent Mode enabled). 
 

 

Figure D-1. Standard Connections to CRS-311

 

 

Figure D-2: CRS-311 in Independent Mode

Primary

5650

Redundant

5650

÷

FL C2

FL C1

RL C1 & C2

C1

C1

C2

C2

Forward

Link

Return

Link

CRS-311 IF

Switched

to Redundant

Traffic

Data #1

M&C

(RS232/485)

Traffic

Data #2

CRS-311

Baseband

Always to

Primary

Primary

5650

Traffic

Data

Redundant

5650

Forward

Link

Return

Link

M&C

(RS232/485)

÷

C1

C1

CRS-311

Baseband

CRS-311 IF

Advertising