1.4.2 CRS-281x IF Switch Module Specifications

Feature

Specification

CRS-281 (70/140MHz)

Specification

CRS-281A/CRS-281L (L-Band)

Tx/Rx Operating Freq

50 to 180 MHz

950-2000 MHz

Tx/Rx Connectors

• TNC (female) with 50Ω path
• BNC (female) with 50Ω or 75Ω path

N-Type (female) with 50

Ω path

Return Loss

18 dB

> 10 dB on external IF ports

Transmit IF Loss/Flatness:

Tx In to Tx Uplink Out
BU In to Any Uplink Out


< 1.5 dB over operating frequency
< 1.5 dB over operating frequency


Tx IF note: Switched by RF relay (1.5 dB
max loss, 40 dB min ON/OFF isolation)

Receive IF Loss/Flatness:

Rx Downlink In to Rx Out
Any Downlink In to BU Out


< 5 dB over operating frequency
< 5 dB over operating frequency


Rx IF note: Passive power splitting
(7 dB max loss)

Tx to Tx Channel Isolation

> 50 dB

> 50 dB

Tx to Rx Channel Isolation

> 60 dB

90dB min

IF Switch Power

From CRS-311 chassis

From CRS-311 chassis

IF, BUC/LNB DC, 10 MHz and
BUC FSK Switching

N/A