CRS-311 1:1 Redundancy Switch

Revision 7

Front Panel Operation

MN/CRS311.IOM

5–16

5.2.4.3.1

(MONITOR: STORED-EVENTS)

Æ VIEW

LOG23: 26/01/00 10:37:32
FT-06 RX ALARM (UP/DN)

 
Use the ▲▼arrow keys to scroll backwards or forwards through the event log entries. Press ENTER 
or CLEAR to return to the previous menu.  
 
The event log can store up to 98 events. When a fault (FT) condition occurs, it is time‐stamped and 
placed in the log.  

 

Similarly,  when  the  fault  condition  clears  (OK),  this  is  also  recorded  as  per  the  following 
example: 
 

LOG24: 26/01/04 10:37:35
OK-06 RX ALARM (UP/DN)

 
Next to the FT/OK indicator is a code for the faulted unit: the TM, (for Traffic Modem), RM (for 
Redundant Modem) or SW (for the Switch). 

5.2.4.4 (MONITOR:) COMMS (Communications State)

COMMS: TRAFFIC: OK
REDUNDANT: FT

 
This screen indicates whether the Switch I/O communications with the modems is good (OK) or 
bad (FT). This does not indicate fault status. 

5.2.4.5 (MONITOR:) IO

T <0000/LRS ?
>0000/LRS=1

 
This screen shows actual communication strings between the Switch and the modems. While in 
this mode, communication is slowed to enable viewing of messages. Because of this, it should 
only be used for troubleshooting purposes. 
 

On  the  top  line:  Switch  controller’s  outbound  messages.  The  first  character  indicates 

the device being addressed (T = Traffic Modem; R = Redundant Modem). 
 

On the bottom line: Modem responses. 

 