Comtech EF Data CRS-311 User Manual

Page 144

Advertising
background image

CRS-311 1:1 Redundancy Switch

Revision 7

Serial-based Remote Product Management

MN/CRS311.IOM

6–14

Parameter Type

Command
(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes:

i.e., ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and qualifier)

Response to query

(Target-to-Controller)

Time

TIM=

6 bytes, numerical Command or Query.

The time from midnight, in the form hhmmss, where
hh = hours, between 00 and 23,
mm = minutes, between 00 and 59, and
ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds from midnight.

TIM= (message OK)
TIM? (received OK, but
invalid arguments)
TIM* (message OK, but not
permitted in current mode)

TIM?

TIM=hhmmss
(see description of
arguments)

TMI/RMI types

N/A

11 Bytes

Query only.
x indicates the TMI/RMI type detected in each slot position:
Positions 1 through 10 are TMIs, where x may be:
0 = none present
1 = CRS-320 rev A
2 = CRS-330
3 = CRS-340 rev A
4 = CRS-340 rev B
5 = CRS-370
6 = CRS-320 rev C
7 = undefined
8 = CRS-341
9 = CRS-316
A = CRS-336
B = undefined
C = CRS-315
D = CRS-325
E = CRS-335
F = CRS-345
G = CRS-365
H = CRS-365D
Position11 is the RMI, where y may be:
0 = none present
7 = CRS-310
D = CRS-307
E = CRS-306
F = CRS-305
Example: XMI=20000000007

N/A XMI?

XMI=xxxxxxxxxxy
(see description of
arguments)

 