CRS-311 1:1 Redundancy Switch

Revision 7

Introduction

MN/CRS311.IOM

1–5

1.2

CRS-311 Switch/Modem Compatibility

Table 1‐1 shows the Comtech EF Data modems that are compatible for use with the CRS‐311 1:1 
Redundancy Switch: 

Table 1-1. CRS-311 Switch/Modem Compatibility

Modem

Optional Switch Modules

CDM-Qx

CRS-281 IF Switch Module (70/140 MHz) - 50Ω or 75Ω BNC

 

Up to one modulator and one demodulator allowed per 
CDM‐Qx/QxL.
 

CDM-QxL

CRS-281A IF Switch Module (L-Band)

Up to one modulator and one demodulator allowed per 
CDM‐Qx/QxL.
 

SLM-5650
SLM-5650A

CRS-281 IF Switch Module (70/140 MHz) - 50Ω TNC
CRS-281L IF Switch Module (L-Band)
CRS-351 ESC Switch Module (IDR Overhead)

 

 

COMPATIBILITY  NOTE:  The  CiM‐25,  Comtech  EF  Data’s  low‐cost  Internet  Protocol 
(IP) Monitor & Control (M&C) interface for existing CEFD modems, is not compatible 
for use on modems operating within a CRS‐311 1:1 redundancy system. Taking this 
prohibition  of  use  under  further  consideration,  the  CiM‐25  should  not, 
under  any 
circumstances, be connected to the “Remote Control
” port on the CRS‐311’s CRS‐230 
System Controller module for control of the Switch and modems. 

 