3 (info:) setup, 4 (info) if-switch, 5 (info:) remcont (remote control info) – Comtech EF Data CRS-311 User Manual

Page 122: 6 (info:) mask (alarms masked info)

Advertising
background image

CRS-311 1:1 Redundancy Switch

Revision 7

Front Panel Operation

MN/CRS311.IOM

5–12

5.2.3.3 (INFO:) SETUP

TRAFFIC MODEM IS ONLINE.
AUTO:OFF BKUP:05 REST:04

 
The  information  provided  here  reflects  some  of  the  settings  defined  with  the  CONFIG: 
submenus.  
 
On the top line: The active (online) modem is listed here.  
 
On the bottom line: The active AUTO mode and the two holdoff times are displayed here. 
 
Press ENTER or CLEAR to return to the previous menu. 

5.2.3.4 (INFO) IF-SWITCH

TRANSPONDER SWITCH IS
PRESENT

 
This screen indicates the presence of the CRS‐281 IF Transponder Switch. Press ENTER or CLEAR 
to return to the previous menu. 

5.2.3.5 (INFO:) REMCONT (Remote Control Info)

REM CNTL: ON RS232
ADDR:0000 9600 BAUD 8N1

 
This  screen  displays  whether  the  unit  is  in  LOCAL  or  REMOTE  mode;  identifies  the  electrical 
interface type; and specifies the unit address, the baud rate, and data format. Press ENTER or 
CLEAR to return to the previous menu. 

5.2.3.6 (INFO:) MASK (Alarms Masked Info)

ALARMS MASKED: MODEM-TX

MODEM-RX

ÉPSU-A ËPSU-B

 
This  screen  displays  the  masked  alarms.  If  an  alarm  is  unmasked,  a  blank  space  occupies  the 
relevant screen position. Although Power Supplies A and B cannot be masked at the same time, 
they  are  shown  together  in  this  example  to  reference  their  respective  screen  positions.  Press 
ENTER or CLEAR to return to the previous menu. 
 