CRS-311 1:1 Redundancy Switch

Revision 7

Installation

MN/CRS311.IOM

2–6

2.2.2 Installing the Modem Optional Side-Mounting Bearingless Rack Slide

Set

The  optional  FP/SL0006  Bearingless  Rack  Slide  Set  may  be  installed  into  the  equipment  rack 
cabinet and onto the sides of each CDM‐Qx/QxL or SLM‐5650/A as shown in Figure 2‐4 and per 
the following procedure: 

 

Step

Task

1

Use the provided mounting hardware to install one slide onto each side of the modem
chassis.

2

Use the provided mounting hardware to install the slide rail components into each interior
side of the equipment rack cabinet.

3

Mount the unit into the front of the equipment rack. Ensure that the slides properly engage
the cabinet-mounted slide rails.

4

Continue to slide the modem into the equipment rack to its final operating position. Then,
use four user-provided screws to secure the modem to the equipment rack’s right and left
threaded front mounting rails (through the front panel mounting slots).

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CEFD Part Number

Description

FP/SL0006

Bearingless Rack Slide Set – 26”

 

Figure 2-4. Installing the Modem Optional Bearingless Rack Slide Set