CRS-311 1:1 Redundancy Switch

Revision 7

Modem, RMI/TMI, and Switch Configuration MN/CRS311.IOM

4–19

 

If the CDM‐Qx/QxL configuration includes Carrier‐in‐Carrier

®

 this holdoff time 

should be no less than 8 seconds. 

 
Follow these steps to set the 

Backup Holdoff Period

 

Step

Task

1

Go to the CONFIG Æ HOLDOFFS menu.

2

Change the BACKUP HOLDOFF to any number in the range of 1 to 99 seconds.

4.6.1.2.2

Set Restore Holdoff Period

The  "Restore  Holdoff"  setting,  which  is  also  programmable  from  1  to  99  seconds,  determines 
the  ability  of  the  Switch  to  automatically  put  the  backed  up  Traffic  Modem  online  again  if  its 
fault clears. 
 
Normally, the failed Traffic Modem taken offline remains offline indefinitely. If the fault clears, 
traffic will be returned to the unit (in Auto mode) only if the Redundant Modem fails.  
 
Follow these steps to set the 

Restore Holdoff Period

 

Step

Task

1

Go to the CONFIG Æ HOLDOFFS menu.

2

Change the RESTORE HOLDOFF to any number in the range of 1 to 99 seconds.

4.6.1.3 Set Alarm Masking

Another  way  to  adjust  the  Switch's  reaction  in  Auto  mode  is  to  mask  modem  faults.  You  may 
disable  modem  Rx,  Tx  or  both  fault  types  so  that  the  Switch  does  not  react  to  them.  This 
masking prevents the Switch from taking automatic action and prevents the logging of the faults 
in the stored events list. These masks are global to all the modems attached to the Switch.  
 
Follow these steps to set 

Alarm Masks

 

Step

Task

1

Go to CONFIG

Æ MASKS Æ MODEM ALARMS.

2

Set the mask parameters as desired.

 