CRS-311 1:1 Redundancy Switch

Revision 7

Serial-based Remote Product Management

MN/CRS311.IOM

6–13

Parameter Type

Command
(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes:

i.e., ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and qualifier)

Response to query

(Target-to-Controller)

Restore Holdoff
Time

RSH=

2 bytes, numerical Command or Query.

The restore holdoff time is the delay when auto mode prepares to
return a modem (previously faulted, now good) back online due to a
different Traffic Modem’s failure:
01-99 = # of seconds after offline Traffic Modem lost its fault before
it is put back online..

RSH= (message OK)
RSH? (received OK, but
invalid arguments found)
RSH* (message OK, not
permitted in current mode)

RSH?

RSH=xx
(see description of
arguments)

Switch Alarm
Mask

SAM=

1 byte, numerical

Command or Query.
x indicates the Switch alarm mask:
0 = no faults masked
1 = PSU-A faults masked
2 = PSU-B faults masked

SAM= (message OK)

SAM? (received OK, but
invalid arguments found)
SAM* (message OK, but not
permitted in current mode)

SAM?

SAM=x
(see description of
arguments)

Switch Global
Configuration

SGC=

29 bytes, numerical Command or Query.

Global configuration of the Switch, in the form:
OasssssssssBNNbbrrMSAssssssss, where:
O = Operating Mode – same as OPM (1 bytes)
a = Active Modem – same as ACT for TM (1 byte)
s = 9 spare bytes
B = Bridge/Backup State – same as BBU (1 byte)
NN = always 01 for the 311
bb = Backup Holdoff Time – same as BKH (2 byte)
rr = Restore Holdoff Time – same as RSH (2 byte)
M = Modem Alarm Mask – same as MAM (1 byte)
S = Switch Alarm Mask – same as SAM (1 byte)
A = Audio Alarm Mask – same as AAM (1 bytes)
s = 8 spare bytes

SGC= (message OK)

SGC? (received OK, but
invalid arguments found)
SGC* (message OK, but not
permitted in current mode)

SGC?

SGC=OasssssssssBNNbbrr
MSAssssssss
(see description of
arguments)

Switch ID

SID=

24 bytes, ASCII

Command or Query.
A user-defined Switch ID, which is a fixed length of 24 characters.
Valid characters include:
Space ( ) * + - , . / 0-9 and A-Z.

SID= (message OK)
SID? (received OK, but
invalid arguments found)
SID* (message OK, but not
permitted in current mode)

SID?

SID=xxxxxxxxxxxxxxxxxxxxx
xxx
(see description of
arguments)

Serial Number

N/A

9 bytes, numerical Query only.

Unit returns its 9-digit serial number.
Example: SNO=176512523

N/A SNO?

SNO=xxxxxxxxx
(see description of
arguments)

Software Revision N/A

5 bytes, numerical Query only.

Unit returns the value of internal software revision installed in the
unit, in the form x.x.x
Example:
SWR=1.0.1 (indicating Version 1.0.1)

N/A SWR?

SWR=x.x.x
(see description of
arguments)