CRS-311 1:1 Redundancy Switch

Revision 7

Cables and Connections

MN/CRS311.IOM

3–4

3.2.2

RS-485 Connections – CRS-311 to Modems

The DB‐9 RS‐485 Multi‐drop Cable provides the communication path between the CRS‐311 and 
the  CDM‐Qx/QxL  modems.  There  are  two  RS‐485  cables  –  both  are  available  from 
Comtech EF Data:  
 

• The  standard  CA‐0000096  shielded  cable  to  guard  against  EMC  (Electromagnetic 

Compatibility) concern, or  
 

• The optional CA‐0000095 ribbon cable.. 

 
Referring to Figure 3‐1, connect and secure the standard CA‐0000096 or optional CA‐0000095 
RS‐485 Multi‐drop Cable between the CRS‐311 and each CDM‐Qx/QxL as follows: 
 

• Connect and secure a CA/WR11418‐1 RS‐485 Terminator to the RS‐485 Multi‐drop Cable 

far‐end connector. 
 

• Connect  and  secure  one  end  of  the  CA/WR11419‐1  9‐pin  Null  Modem  Cable  to  the 

DB‐9F connector labeled “485 Pass‐Through” on the CRS‐311 CRS‐230 System Controller 
module. 

 

• Connect and secure the appropriate RS‐485 Multi‐drop Cable to the CDM‐Qx/QxL and to 

the Null Modem Cable DB‐9M connector. 

3.2.3

Control ‘Y’ Cable Connections – CRS-311 to Modems

All Data Traffic configurations require that the CA‐0000009 Control ‘Y’ Cable must be connected 
between the CRS‐311 and to each CDM‐Qx/QxL as follows: 
 
Referring to Figure 3‐2 through Figure 3‐6: 
 

From the HD‐15F connector labeled “J1” on the RMI or TMI, to  
 

The  DB‐15M  connectors  labeled  “Alarms”  on  the  CDM‐Qx/QxL  modulator  and 
demodulator modules (located on the modem chassis rear panel). 

 

Further: 

 

From  the Control ‘Y’ Cable connector labeled “J1” to  

 

The modulator “Alarms” connector.  

 
‐and‐ 
 

From the Control ‘Y’ Cable connector labeled “J2” to  

 

The demodulator “Alarms” connector.  