Appendix C. ADDRESSING

SCHEME INFORMATION

C.1

Introduction to Addressing

A  CRS‐311  1:1  Redundancy  Switch  provides  1:1  modem  redundancy;  that  is,  it  is  capable  of 
controlling one Traffic Modem and one Redundant Modem.  
 
You can remotely communicate to  the Switch or either of  the  modems, using the appropriate 
addresses, via EIA‐232 or EIA‐485 using the DB‐9M “Remote Control” connector on the CRS‐230 
System Controller module that is installed in the CRS‐311. 
 

For Switch‐to‐modem communication using SLM‐5650/5650A modems: The Switch uses 

serial communication via the HD‐15 Control Cable that is connected between each TMI/RMI 
and the modems.  

 

For  Switch‐to‐modem  communication  using  CDM‐Qx/QxL  modems:  The  Switch  uses 

EIA‐485  communications  via  a  DB‐9  multi‐drop  cable  that  is  connected  from  the  “485 
Pass‐Through” connector on the CRS‐230, then daisy‐chained to each of the modems. 

 
If the modems are configured for EDMAC framing, Monitor & Control (M&C) information may 
be communicated to the modems and transceivers at the distant‐end of the link. In order for an 
M&C application to be able to communicate with the various modems connected to the Switch, 
the correct addresses must be used. 
 
This appendix defines the address requirements to allow M&C of the Switch and the modems that 
may be included in a CRS‐311 1:1 Redundancy Switch system.

 