OPERATION

PAC186

Stainless Steel##

Air Plasma / Air & CH

4

Shield

70 Amp Cutting

Shield
020796

Nozzle
020647

Electrode
120112

Retaining Cap
020795

Swirl Ring
020789

PAC186 Torch
120349

Shield Cap
020634/020687

Material

Thickness

(GA)

(in)

(mm)

Arc

Voltage

(volts)

Torch

Standoff**

(in)

(mm)

Travel

Speed

(ipm)

(m/min)

Pierce

Delay

(dial)

(sec)

Initial

Piercing

Height

***

(in)

(mm)

10

0.135

3.4

75

0

100

0

35

134

0.060

1.5

100

2.54

0.140

3.5

1

0.3

3/16

4.8

75

0

60

3

35

139

0.080

2.0

80

2.00

0.140

3.5

1.5

0.4

1/4

6.4

75

0

30

10

35

149

0.140

3.5

55

1.40

0.180

4.5

2

0.5

3/8

9.5

75

0

30

10

35

164

0.140

3.5

30

0.76

0.200

5.0

2

0.5

1/2

12.7

75

0

40

20

50

189

0.250

6.3

25

0.64

****

****

Air and CH

4

gas inlet pressures must be between 105 - 135 psi (7.2 - 9.2 bar) for all material thickness.

#

Refer to LCD display Figure 4-3.

##

Stainless steel plate sometimes comes with a protective plastic film. Remove film prior to cutting.

* Slightly increasing the test preflow Air flowrates may increase piercing capability on the thicker materials listed above.

However, increasing the preflow flowrates too much may affect plasma starting reliability (misfiring).

** Torch standoff tolerances are ± 0.005 inch (± 0.125 mm). When using a THC, tolerances are ± 1 volt.

*** Measured from tips of shield adapter 020796.

**** Piercing 1/2 inch (12.7 mm) stainless steel is not recommended, it will shorten consumable life. Starting cuts at the edge of

the metal is recommended.

Counter clockwise (CCW) consumables are available for mirror image cutting. Refer to Section 6, Parts List.

If problems occur with the cutting process, and the flowrates are suspect, refer to Section 5, Maintenance, Gas System Back

Test Cut

Flowrates (%)

Shield

Air

CH

4

(3)

#

(4)

#

Plasma

Air
(5)

#

(6)

#

Test Preflow*

Flowrates (%)

Preflow

Air

CH

4

(1)

#

(2)

#

Advertising