MAINTENANCE

PS ERR=7

RAMPUP BLOWOUT ERROR

Informs operator that arc was

extinguished after current transfer to

workpiece, but before steady-state

operation.

Set correct torch
standoff. Refer to Cut
Charts in Section 4.

No

Set correct gas
flowrates. Refer to Cut
Charts in Section 4.

No

Yes

Is torch standoff

correct ?

Are gas flowrates

set to correct values ?

Check for leaks or
twists in gas lead set.

No

Yes

Are torches back

pressures

within recommended

ranges ?

Reduce time delay
for machine motion
at CNC.

Yes

No

Yes

Is machine motion

delay too long ?

Continued

on next

page