MAINTENANCE

Gas System (GS-ERR)

Error Message

Error Code

Description

NO ERROR

0

LOW PLASMA GAS ERR

1

This error signal is issued if the plasma gas inlet pressure is
below 105 psig (7.2 bar).

LOW SHIELD GAS ERR

2

This error signal is issued if the shield gas inlet pressure is
below 105 psig (7.2 bar).

HIGH PLASMA GAS ERR

3

This error signal is issued if the plasma gas inlet pressure is
above 135 psig (9.3 bar).

HIGH SHIELD GAS ERR

4

This error signal is issued if the shield gas inlet pressure is
above 135 psig (9.3 bar).

MV1 ERR*

5

This error signal is issued when the MV1 motor valve does
not move when commanded. When this error occurs service
is required.

MV2 ERR*

6

This error signal is issued when the MV2 motor valve does
not move when commanded. \When this error occurs service
is required.

MV3 ERR*

7

This error signal is issued when the MV3 motor valve does
not move when commanded. When this error occurs service
is required.

MV4 ERR*

8

This error signal is issued when the MV4 motor valve does
not move when commanded. When this error occurs service
is required.

MV5 ERR*

9

This error signal is issued when the MV5 motor valve does
not move when commanded. When this error occurs service
is required.

MV6 ERR*

10

This error signal is issued when the MV6 motor valve does
not move when commanded. When this error occurs service
is required.

* The plasma system will have to be powered down and then restarted if any of the motor valve errors occur.