MAINTENANCE

PS ERR=6

TRANSFER TIMEOUT ERROR

(Continued)

Connect or replace
transfer current
sensor CS1.

Set correct
value for current.

No

Install new
consumables of
correct type.

No

Yes

Yes

Is current setting

correct ?

Yes

Are consumables of

correct type properly

installed & in good

condition ?

Replace control PCB
1XPCB3.
Fig 6-2 (4)

No

Yes

Is transfer current

sensor CS1

disconnected or

defective ?

Fig 6-9 (4)