16

MAINTENANCE

GS ERR=1

LOW PLASMA GAS ERROR

Informs operator that plasma gas inlet

pressure is below 105 psi. Plasma gas

inlet pressure is indicated on LCD

display Figure 5-3.1

Contact Hypertherm
technical service.

Increase pressure or
replenish gas supply.

Yes

Replace plasma
gas supply hose.

Yes

No

Is plasma gas inlet

pressure low ?

No

Is plasma gas supply

hose restricted ?

Gas System Error Message Flow Diagrams