3-14

HD3070 with Automatic Gas Console

Instruction Manual

16

INSTALLATION

Figure 3-6

Automatic Gas Console Removal Procedure and Mounting Dimensions

To remove the automatic gas console from the power
supply:

1. Remove 14 screws securing cover to gas console.

2. Remove cover.

3. Locate and remove four screws securing gas console to

power supply.

Caution:

The automatic gas console weighs
83 pounds (37.7 kg). Use care when lifting
and moving the console.

4. When lifting gas console, note the four flat washers

between the power supply and gas console. Reinstall
screws with flat washers into screw holes on power
supply for future use.

Bottom

10 in.

(254 mm)

24 in. (610 mm)

22 in.

(559 mm)

Hole size

0.250 in.

(6.350 mm)

21.75 in. (552 mm)

12.875 in.

(327 mm)

Advertising