Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 200

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-75

16

MAINTENANCE

Tighten (Torque to
12-15 inch pounds)

Loosen

Install New Water Tube

Loosening and Tightening Water Tube

O-Ring

Water Tube

Gold Ring
(location in torch)

Nut Driver
(4.5 mm)

Water Tube

Figure 5-10

Water Tube Removal and Replacement

Be careful not to dislodge
gold ring when installing
water tube. See Caution
and step 3 on previous page.

Advertising